MAXLOGIC & MAVIGARD FIRE – GAS DETECTION SYSTEMS
- Description
Description
Intelligent analog-address fire alarm systems, which are often used in large and medium-sized projects and intelligent buildings, can indicate in detail where the fire occurred. Smoke detectors, Smoke linear detectors, Heat detectors, and multi-sensor detectors allow the user to quickly and efficiently detect the fire. Addressable gas detectors can detect gas leaks and prevent potential hazards. In addition, residents can manually activate the fire alarm system with manual detectors. Weatherproof sounders, Light sounders and Light and Sounders can loudly and visually alert people in a building in case of a fire. The fire alarm system implemented during the control of the control panel ensures the safe evacuation of people in the building, firefighting, etc. Intelligent addressable fire safety and alarm systems can be remotely controlled using graphical manager monitoring and control software.
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
Product Code: ML-123X
Brand: Maxlogic & Mavigard by MAVILI

- Compatible with EN 54-2 and EN 54-4 standards
- Expandable up to 8 loops, max. 1016 address capacity for each panel.
- Real time clock.
PANEL MODELS
Product Code | Loop | Address | Product Code | Loop | Address |
---|---|---|---|---|---|
ML-1230.N | 0 | 0 | ML-1237 | 7 | 889 |
ML-1231 | 1 | 127 | ML-1238 | 8 | 1016 |
ML-1233 | 3 | 381 | |||
ML-1234 | 4 | 508 | |||
ML-1235 | 5 | 635 | |||
ML-1236 | 6 | 762 |
Product Code: ML-124X.P
Brand: Maxlogic & Mavigard by MAVILI

- Compatible with EN 54-2 and EN 54-4 standards
- Expandable up to 8 loops, max. 1016 address capacity for each panel.
- Event logs can be printed instantly or collectively by the printer module.
PANEL MODELS
Product Code | Loop | Address | Product Code | Loop | Address |
---|---|---|---|---|---|
ML-1240.N | 0 | 0 | ML-1247.P | 7 | 889 |
ML-1241.P | 1 | 127 | ML-1248.P | 8 | 1016 |
ML-1242.P | 2 | 254 | |||
ML-1243.P | 3 | 381 | |||
ML-1244.P | 4 | 508 | |||
ML-1245.P | 5 | 635 | |||
ML-1246.P | 6 | 762 |
Product Code: ML-125XX
Brand: Maxlogic & Mavigard by MAVILI

- Compatible with EN 54-2 and EN 54-4 standards
- Expandable loops up to 16 loops, max. 2032 address capacity for each panel
- Protection from electromagnetic interference
- Surface mount technology
- Real time clock
PANEL MODELS
Product Code | Loop | Address | Product Code | Loop | Address |
---|---|---|---|---|---|
ML-1250.N | 0 | 0 | ML-1259 | 9 | 1143 |
ML-1251 | 1 | 127 | ML-12510 | 10 | 1270 |
ML-1252 | 2 | 254 | ML-12511 | 11 | 1397 |
ML-1253 | 3 | 381 | ML-12512 | 12 | 1524 |
ML-1254 | 4 | 508 | ML-12513 | 13 | 1651 |
ML-1255 | 5 | 635 | ML-12514 | 14 | 1778 |
ML-1256 | 6 | 762 | ML-12515 | 15 | 1905 |
ML-1257 | 7 | 889 | ML-12516 | 16 | 2032 |
ML-1258 | 8 | 1016 |
Product Code: ML-125XX.NPTA
Brand: Maxlogic & Mavigard by MAVILI

- Compatible with EN 54-2 and EN 54-4 standards
- Expandable loops up to 16 loops, max. 2032 address capacity for each panel
- Protection from electromagnetic interference
- Surface mount technology
- Real time clock
PANEL MODELS
Product Code | Loop | Address | Product Code | Loop | Address |
---|---|---|---|---|---|
ML-1250.NPTA | 0 | 0 | ML-1259.NPTA | 9 | 1143 |
ML-1251.NPTA | 1 | 127 | ML-12510.NPTA | 10 | 1270 |
ML-1252.NPTA | 2 | 254 | ML-12511.NPTA | 11 | 1397 |
ML-1253.NPTA | 3 | 381 | ML-12512.NPTA | 12 | 1524 |
ML-1254.NPTA | 4 | 508 | ML-12513.NPTA | 13 | 1651 |
ML-1255.NPTA | 5 | 635 | ML-12514.NPTA | 14 | 1778 |
ML-1256.NPTA | 6 | 762 | ML-12515.NPTA | 15 | 1905 |
ML-1257.NPTA | 7 | 889 | ML-12516.NPTA | 16 | 2032 |
ML-1258.NPTA | 8 | 1016 |
Telephone Module
In case of fire or emergency events, communication can be provided between security center, firefighter’s telephones and telephones on the other panels via firefighter’s telephone control unit.
Announce Module
In case of fire and emergency events, announce module can be integrated to all kinds of present announce systems (all brands and models) via alarm announce matrix panel, it provides to live announcement to determined areas via panel.
Printer Module
Event logs can be printed instantaneously or collectively by the printer module. Since the printer is thermal type, running out of ink is no longer a problem.
Telephone / Announce<
Control Unit
The use of telephone module and public announce module Over the panel is realized with the LCD designed control unit.
Product Code: 7” TFT Mimic Panel
Brand: Maxlogic & Mavigard by MAVILI

- Compatible with EN 54-2 and EN 54-4 standards
- Expandable loops up to 16 loops, max. 2032 address capacity for each panel
- Protection from electromagnetic interference
- Surface mount technology
- Real time clock
PANEL MODELS
Product Code | Description |
---|---|
ML-1280 | 7” TFT mimic panel |
ML-1621 | ML-1280 7” TFT Mimic Panel Software |
INTELLIGENT ADDRESSABLE FIRE DETECTORS

Intelligent addressable fire detectors, offering high performance by the VIP communication protocol, provide a high level of reliability as a result of stable detection feature.
- Compatible with EN 54-5, EN 54-7 and EN 54-17 standards
- Microprocessor controlled
- Twin fire alarm indicators for 360° viewing
- RY LED glows Red in case of fire, Yellow in case of pollution and fault conditions
- Remote indicator output
- Optional Short circuit isolator module
- Compatible with ML-0140 and ML-0141 series maxlogic detector sockets
- Compatible with ML-0121 series surface mounting back box
- Compatible with ML-0150 series recessed mounting base
- Easy mounting and dismounting
ADDRESSABLE FIRE DETECTOR MODELS
Product Code | Description |
---|---|
ML-1110 | Optical smoke detector |
ML-1130 | Heat detector |
ML-1130BS | Class BS heat detector with mounting base |
ML-1140 | Multi-sensor detector |
ML-1110.SCI | Optical smoke detector, with short circuit isolator |
ML-1130.SCI | Heat detector, with short circuit isolator |
ML-1140.SCI | Multi-sensor detector, with short circuit isolator |
ML-0140 | Detector mounting base |
ML-0141 | Mounting base c/w buzzer |
ML-0150 | Recessed mounting base |
ML-0121 | Weatherproof surface mounting back box |
INTELLIGENT ADDRESSABLE GAS DETECTORS

Designed with surface mounting Technologies to detect smoke through infrared beams in places that have high and wide areas (warehouse, malls, etc.)
- Compatible with EN 50194-1 standard
- System normal operation condition, faults on detector and gas alarm events can be followed via LEDs
- Built-in Buzzer, LEDs and buzzer can be tested via test button
- Can be directly connected to loop
- 5 years sensor life under normal operating conditions
- Max. 127 gas detectors per loop
- Relay output models can work with fire and security alarm control panels
- Models available with two level threshold value
- Models with both 24V DC and 230V AC power supply are available
ADDRESSABLE GAS DETECTOR MODELS
Product Code | Description |
---|---|
AGD-1224L.VIP | Intelligent addressable LPG detector, 24V DC |
AGD-1224M.VIP | Intelligent addressable natural-gas (methane) detector, 24V DC |
AGD-1224EC.VIP | Intelligent addressable carbon-monoxide detector, 24V DC, electrochemical |
AGD-220L.VIP | Intelligent addressable LPG detector, 230V AC |
AGD-220M.VIP | Intelligent addressable natural-gas (methane) detector, 230V AC |
AGD-220EC.VIP | Intelligent addressable carbon-monoxide detector, 230V AC, electrochemical |
ML-0120 | Surface mounting back box |
INTELLIGENT ADDRESSABLE BEAM

Designed with surface mounting Technologies to detect smoke through infrared beams in places that have high and wide areas (warehouse, malls, etc.)
Maxlogic beam type smoke detector consists of 2 parts; receiver and transmitter. They should be installed as facing each other between the distance of 5-100m.
Reflective beam type smoke detector consists 2 parts as a receiver/transmitter unit and reflector. Unit and reflector should be mounted as facing each other, distance is 5-35 meters with 1 reflector and 5-50 meters with using 4 reflectors.
Detectors detect the light obstruction percentage caused by the smoke created by fire.
- Ability to adjust itself to polluted and dirty environment
- Three sensitivity levels can be easily adjusted
- Continuous control of communication against the faults
- With beam type smoke detector 1500 m2, with reflective beam type smoke detector 750 m2 protection area
- Easy programming buttons
- LED indicators for power, fire and fault conditions
- Intelligent addressable and conventional models
- Short circuit isolator models
- Receiver-Transmitter or reflective models
- 2 digit numerical screen for easy commissioning and setup
ADDRESSABLE BEAM DETECTOR MODELS
Product Code | Description |
---|---|
ML-1170 | Intelligent addressable beam type smoke detector (included receiver-transmitter) |
ML-1170.SCI | Intelligent addressable beam type smoke detector (included receiver-transmitter) with short circuit isolator |
ML-1173 | Intelligent addressable reflective beam type smoke detector |
ML-1173.SCI | Intelligent addressable reflective beam type smoke detector, with short circuit isolator |
ML-0171 | Beam type smoke detector reflector, with 1 reflector |
ML-0174 | Beam type smoke detector reflector, with 4 reflector |
INTELLIGENT ADDRESSABLE SOUNDER/ BEACON / SOUNDER & BEACON

Intelligent addressable loop-powered sounder/sounder beacon; designed for intelligent addressable system, with full VIP communication protocol compatibility.
- Compatible with EN 54-3 / EN 54-23 standards
- Short circuit isolator models compatible with EN 54-17
- ‘Soft’ addressable by use of address programmer
- Able to integrate into the cause effect scenarios
- Compatible with all addressable fire alarm control panels
ADDRESSABLE SOUNDER / BEACON MODELS
Product Code | Description |
---|---|
ML-1410 | Intelligent addressable system sounder |
ML-1410.SCI | Intelligent addressable system sounder with short circuit isolator |
ML-1420 | Intelligent addressable system beacon |
ML-1420.SCI | Intelligent addressable system beacon with short circuit isolator |
ML-1430 | Intelligent addressable system sounder & beacon |
ML-1430.SCI | Intelligent addressable system sounder & beacon with short circuit isolator |
WEATHERPROOF INTELLIGENT ADDRESSABLE SOUNDER / BEACON / SOUNDER & BEACON
Intelligent addressable loop-powered sounder/sounder beacon; designed for intelligent addressable system, with full VIP communication protocol compatibility.
- Compatible with EN 54-3 / EN 54-23 standards
- Short circuit isolator models compatible with EN 54-17
- Adjustable different 32 voice tone options
- IP33 / IP65 high protection class options
- Suitable for outdoor use
- Able to integrate into the cause effect scenarios
- Compatible with all addressable fire alarm control panels
- PCB protected by metal case
- Aesthetic design
- Production by surface mount technology
- Stable sensitivity
WEATHERPROOF ADDRESSABLE SOUNDER / BEACON MODELS
Product Code | Description |
---|---|
ML-1440 | Intelligent Addressable System Sounder, Weatherproof (IP33) |
ML-1440.SCI | Intelligent Addressable System Sounder, Weatherproof (IP33), Short Circuit Isolator |
ML-1450 | Intelligent Addressable System Beacon, Weatherproof (IP33) |
ML-1450.SCI | Intelligent Addressable System Beacon, Weatherproof (IP33), Short Circuit Isolator |
ML-1460 | Intelligent Addressable System Sounder & Beacon, Weatherproof (IP33) |
ML-1460.SCI | Intelligent Addressable System Sounder & Beacon, Weatherproof (IP33), Short Circuit Isolator |
ML-1470 | Intelligent Addressable System Sounder, Weatherproof (IP65) |
ML-1470.SCI | Intelligent Addressable System Sounder, Weatherproof (IP65), Short Circuit Isolator |
ML-1480 | Intelligent Addressable System Beacon, Weatherproof (IP65) |
ML-1480.SCI | Intelligent Addressable System Beacon, Weatherproof (IP65), Short Circuit Isolator |
ML-1490 | Intelligent Addressable System Sounder & Beacon, Weatherproof (IP65) |
ML-1490.SCI | Intelligent Addressable System Sounder & Beacon, Weatherproof (IP65), Short Circuit Isolator |
INTELLIGENT ADDRESSABLE MANUAL CALL POINTS

Design according to the EN 54-11 standards, with easy to install and easy to use features and useful accessories, the addressable fire alarm manual call points offer advanced and stable working performance.
- Compatible with EN 54-11 / EN 54-17 standards
- Compatible with all addressable fire alarm control panels
- Surface mount or flush mount
- Communication interrupt for fast fire alarm detection in 1.5 sec.
- Transparent protection cover
- Short circuit isolator models
- Production by surface mount technology
ADDRESSABLE MANUAL CALL POINT MODELS
Product Code | Description |
---|---|
ML-1710 | Intelligent addressable system manual call point, resettable |
ML-1710.SCI | Intelligent addressable system manual call point, resettable, short circuit isolator |
ML-1730 | Intelligent addressable system manual call point, weatherproof (IP67), resettable |
ML-1730.SCI | Intelligent addressable system manual call point, weatherproof (IP67), resettable, short circuit isolator |
ML-0710 | Transparent protection cover |
INTELLIGENT ADDRESSABLE INPUT / OUTPUT MODULES

Monitor and control modules, offering high performance by the VIP communication protocol, can be configured to operate in cause-effect scenario and fire automation can be performed.
Switch monitor inputs are used for monitoring external dry switch relay output. Switches have normally open and normally close operate features. In case of changing of switch position, event type that is detected by panels can be determined by users.
The module has one relay output with voltage-free, bipolar contact max. load of 30V DC, 1A . The relay can operate as normally open or normally close.
Zone monitoring Inputs are used to monitor the conventional type detectors and manual call points. In case of change of Input status, events type that are detected by panel can be determined by users.
24V DC 500mA sounder output can be activated within fire automation as required. 24V DC 500mA sounder output can be arranged according to event type that is determined by users.
The modules have SCI, internal short circuit isolator, in case of short circuit events, isolates the line.
- Compatible with EN 54-17 and EN 54-18 standards
- Optional short circuit isolator models
- LED-indicated activation, fault, and communication status
- Easy mounting with rail system
- 2/1 I/O module with 2 zone monitoring inputs 1 sounder output option or 2 dry contact monitoring inputs 1 dry contact relay output option
- 4/2 I/O module with 4 dry contact monitoring inputs 2 dry contact relay outputs option
INPUT / OUTPUT MODULE MODELS
Product Code | Description |
---|---|
ML-1361 | Intelligent addressable system relay control module, 1-way output |
ML-1361.SCI | Intelligent addressable system relay control module, 1-way output, with short circuit isolator |
ML-1362 | Intelligent addressable system switch monitor module, 1-way input |
ML-1362.SCI | Intelligent addressable LPG detector, 230V AC |
ML-1363 | Intelligent addressable system 2/1 I/O module (2 inputs / 1 output) |
ML-1363.SCI | Intelligent addressable system 2/1 I/O module (2 inputs / 1 output), with short circuit isolator |
ML-1366 | Intelligent addressable system 4/2 I/O module (4 inputs / 2 outputs) |
ML-1366.SCI | Intelligent addressable system 4/2 I/O module (4 inputs / 2 outputs), with short circuit isolator |
ML-1371 | Intelligent addressable system sounder control module, 1-way output |
ML-1371.SCI | Intelligent addressable system sounder control module, 1-way output, with short circuit isolator |
ML-1372 | Intelligent addressable system zone monitor module, 1-way input |
ML-1372.SCI | Intelligent addressable system zone monitor module, 1-way input, with short circuit isolator |
ML-1373 | Intelligent addressable system 2/1 I/O Module (2 inputs / 1 output) |
ML-1373.SCI | Intelligent addressable system 2/1 I/O module (2 inputs / 1 output), with short circuit isolator |
ML-1380 | Intelligent addressable system short circuit isolator |
ML-1390 | Intelligent addressable system short circuit isolator |
ML-0320 | Intelligent addressable system 2-I/O module protection box |
LOOP POWERED BASE SOUNDER / SOUNDER & BEACON

Maxlogic intelligent addressable loop-powered base sounder is designed for indoor use, In case of fire, user is warned by audible and visible warnings. Sounders are microprocessor controlled and outputs can be programmed to work within cause-effect scenarios.
Its primary application is to be installed under intelligent analogue addressable smoke and heat detectors to provide both detection and alarm at the same point, reducing wiring and installation costs.
- Compatible with EN 54-3 standard
- Specially designed for indoor use
- Loop-powered
- 85 dB sound output, 8 tones and volume control
- It can be used as a standalone sounder/sounder beacon
BASE SOUNDER MODELS
Product Code | Description |
---|---|
ML-1101 | Addressable loop powered base sounder |
ML-1102 | Addressable loop-powered base sounder beacon |
SMPS POWER SUPPLY

SPMS power supplies have a stable sensitivity, produced by using surface mount technology and compatible with all Maxlogic & Mavigard series products.
- Compatible with EN 54-4 standard
- In the case of electrical failure, power is supplied from battery, which are automatically recharged
- Automatic battery charge circuit
- Battery charge voltage according to ambient temperature
- Earth fault, battery fault (charge fault, low voltage fault, no battery connection fault), power and fuse faults are monitored on the power supply unit
- Dry contact relay output for faults
- In case of electrical failure, supply from battery and protected from short circuit and over current
- Battery temperature measurement and automatically arrangement for battery charge voltage
POWER SUPPLY MODELS
Product Code | Description |
---|---|
ML-0515 | SPMS power supply, 5A |
ML-5110 | SPMS power supply, 10A |
Conventional fire alarm systems are used in small and medium-sized projects can report the source of the fire on a regional basis. Smoke detectors, Smoke linear detectors, Heat detectors, and multi-sensor detectors allow to quickly and efficiently detect a fire. Gas detectors can detect a gas leak and prevent potential danger. In addition, residents can manually activate the fire alarm system with manual detectors. Weatherproof sounders, light sounders and sound, and sounders can loudly and visually alert people in a building in the event of a fire.
CONVENTIONAL FIRE ALARM PANELS
Product Code: ML-221XX
Brand: Maxlogic & Mavigard by MAVILI

- Compatible with EN 54-2 and EN 54-4 standards
- 2, 4, 8 and 16 zones
- 230V AC 50 Hz power supply input
- Panel provides to make network connection up to 32 panel with using MGRP-64 Repeater Panel
PANEL MODELS
Product Code | Description |
---|---|
ML-22102 | Conventional fire alarm control panel, 2 zone |
ML-22104 | Conventional fire alarm control panel, 4 zone |
ML-22108 | Conventional fire alarm control panel, 8 zone |
ML-22116 | Conventional fire alarm control panel, 16 zone |
Product Code: ML-222X
Brand: Maxlogic & Mavigard by MAVILI

PANEL MODELS
Product Code | Description |
---|---|
ML-2222 | Conventional fire alarm control panel, 2 zone |
ML-2224 | Conventional fire alarm control panel, 4 zone |
ML-2228 | Conventional fire alarm control panel, 8 zone |
Product Code:MGRP-64
Brand: Maxlogic & Mavigard by MAVILI
CONVENTIONAL REPEATER PANEL
- Compatible with EN 54-2 and EN 54-4 standards
- Compatible with ML-221XX series conventional fire alarm panels
- RS-485 communication protocol
- Network line up to 1200 meters
Product Code:ML-0314
Brand: Maxlogic & Mavigard by MAVILI
SOUNDER EXPANSION PANEL
- Compatible with EN 54-18 and EN 54-4 standards
- Compatible with all Intelligent addressable and conventional panels
- 4 supervised sounder output, each are 1A, 24V DC
- Sounder outputs are supervised and continuously monitor for open and short circuit.
- Direct supply from the batteries when the power supply is cut
- Battery charge voltage is automatically adjusted according to ambient temperature
CONVENTIONAL FIRE DETECTORS

Ergonomic and user friendly conventional fire alarm detectors are designed for maximum protection with their stability and sensitivity.
- Compatible with EN 54-5 and EN 54-7 standards
- Twin LED indicators for 360° view
- 2 pcs red LEDs (the light flashes continuously in case of fire-situation, the light flashes once per 8 second in case of normal-status, the light flashes twice per 8 second in case of fault-status)
- Microprocessor controlled
- Compatible with ML-0140 series mounting base c/w relay
- Compatible with ML-0150 series recessed ceiling mounting back box
- Compatible with ML-0121 series surface mounting back box
- Remote indicator output
- Clips switch structure ensures the electrical contact
CONVENTIONAL GAS DETECTOR MODELS
Product Code | Description |
---|---|
ML-2110 | Optical smoke detector |
ML-2120 | Fixed heat detector |
ML-2130 | Combined heat detector |
ML-2130BS | Class BS heat detector with mounting base |
ML-2140 | Multi-Sensor detector |
ML-0140 | Detector mounting base |
ML-0141 | Mounting base c/w buzzer |
ML-0150/td> | Recessed mounting base |
ML-0121 | Surface mounting back box |
CONVENTIONAL GAS DETECTORS

Gas detectors are compatible with conventional fire alarm panels, and provide a sensitive and stable operating performance. User-friendly Mavigard gas detectors provide wide applicability and reliable gas detection.
- Compatible with EN 50194-1
- System normal operation condition, faults on detector and gas alarm events can be followed via LEDs
- LEDs and buzzer can be tested via test button
- Built-in Buzzer
- Can be directly connected to loop
- 5 years sensor life under normal operating conditions
- Max. 127 gas detectors per loop
- Relay output models that work with fire and security alarm control panels
- Models with two level threshold value
- Models with external 24V DC / 230V AC power supply
CONVENTIONAL GAS DETECTOR MODELS
Product Code | Description |
---|---|
GDR-1224L | LPG (buthane+propane) detector, 12/24V DC with relay |
GDR-1224M | Methane (natural gas) detector, 12/24V DC with relay |
GDR-220L | LPG (buthane+propane) detector, 230V AC with relay |
GDR-220M | Methane (natural gas) detector, 230V AC with relay |
GD2R-12EC | Carbon monoxide gas detector (CO), 12V DC, 2-level alarm output, electrochemical |
GD2R-24EC | Carbon monoxide gas detector (CO), 24V DC, 2-level alarm output, electrochemical |
GD2R-220EC | Carbon monoxide gas detector (CO), 230V DC, 2-level alarm output, electrochemical |
TGDR-1224M | Methane (natural gas) detector, 12/24V DC with relay |
ML-0120 | Surface mounting back box |
INTELLIGENT ADDRESSABLE BEAM

Designed with surface mounting Technologies to detect smoke through infrared beams in places that have high and wide areas (warehouse, malls, etc.)
Maxlogic beam type smoke detector consists of 2 parts; receiver and transmitter. They should be installed as facing each other between the distance of 5-100m.
Reflective beam type smoke detector consists 2 parts as a receiver/transmitter unit and reflector. Unit and reflector should be mounted as facing each other, distance is 5-35 meters with 1 reflector and 5-50 meters with using 4 reflectors.
Detectors detect the light obstruction percentage caused by the smoke created by fire.
- Ability to adjust itself to polluted and dirty environment
- Three sensitivity levels can be easily adjusted
- Continuous control of communication against the faults
- With beam type smoke detector 1500 m2, with reflective beam type smoke detector 750 m2 protection area
- Easy programming buttons
- LED indicators for power, fire and fault conditions
- Intelligent addressable and conventional models
- Short circuit isolator models
- Receiver-Transmitter or reflective models
- 2 digit numerical screen for easy commissioning and setup
CONVENTIONAL BEAM DETECTOR MODELS
Product Code | Description |
---|---|
ML-2170 | Maxlogic conventional beam type smoke detector (receiver and transmitter is included) |
ML-2173 | Conventional reflector beam type smoke detector |
ML-0171 | Beam type smoke detector reflector, with 1 reflector |
ML-0174 | Beam type smoke detector reflector, with 4 reflector |
CONVENTIONAL SOUNDER

Maxlogic series conventional sounders provide stable performance in indoor applications and are compatible with all conventional panels.
Maxlogic series conventional sounder beacon generates audible and visual signal, in addition to these features
- Compatible with EN 54-3
- Surface mount or flush mount
- Compatible with all conventional fire alarm panels
CONVENTIONAL SOUNDER / BEACON MODELS
Product Code | Description |
---|---|
ML-2410 | Conventional sounder |
ML-2420 | Conventional beacon |
ML-2430 | Conventional sounder & beacon |
Conventional Sounder / Beacon /Sounder & Beacon, Weatherproof
Maxlogic series conventional sounders are weather-proof audible warning devices and suitable for outdoor use.
- Compatible with EN 54-3 and EN 54-23
- Adjustable different 32 voice tone options
- Adjustable flash frequency and coverage area
- IP33 / IP65 high protection class options
- Suitable for outdoor use
- White, strong LED flasher
WEATHERPROOF CONVENTIONAL SOUNDER / BEACON MODELS
Product Code | Description |
---|---|
ML-2440 | Conventional Sounder, Weatherproof (IP33) |
ML-2450 | Conventional Beacon, Weatherproof (IP33) |
ML-2460 | Conventional Sounder & Beacon, Weatherproof (IP33) |
ML-2470 | Conventional Sounder, Weatherproof (IP65) |
ML-2480 | Conventional Beacon, Weatherproof (IP65) |
ML-2490 | Conventional Sounder & Beacon, Weatherproof (IP65) |
CONVENTIONAL MANUAL CALL POINTS

Design according to the EN 54-11 standards, with easy to install and easy to use features and useful accessories, the addressable fire alarm manual call points offer advanced and stable working performance.
- Easy resettable
- LED indicated activation
- Compatible with EN 54-11 standards
- Surface mount or flush mount
- Compatible with all conventional fire alarm panels
- Transparent protection cover
CONVENTIONAL MANUAL CALL POINT MODELS
Product Code | Description |
---|---|
ML-2710 | Manual call point, resettable |
ML-0710 | Transparent protection cover |
CONVENTIONAL ACCESSORIES

Smoke detector tester is a functional testing product for ionization and optical smoke detectors.
- UL listed
- Non-flammable
- Non-toxic
- Does not damage the detector
- Doesn’t damage plastic surface and internal structure
BASE SOUNDER MODELS
Product Code | Description |
---|---|
SMOKE SABRE 01-001 | Smoke detector tester / sabre |
Conventional series fire extinguishing control panel operates on cross-zone principle, has 4 detection zones and one extinguishing release output which is programmable according to the zone requirements. Conventional extinguishing control panel is microprocessor controlled, offers high performance and can easily be integrated into all extinguishing projects.
CONVENTIONAL FIRE EXTINGUISHING CONTROL PANELS
Product Code:ML-322
Brand: Maxlogic & Mavigard by MAVILI

Conventional series fire extinguishing control panel operates on cross-zone principle, has 4 detection zones and one extinguishing release output which is programmable according to the zone requirements. Conventional extinguishing control panel is microprocessor controlled, offers high performance and can easily be integrated into all extinguishing projects.
- Compatible with EN 12094-1, EN 54-2 and EN 54-4 standards
- 4 detection zones, 1 extinguishing zone
- Extinguishing-related front panel LEDs and LCD screen provide full system information
- Display of two warnings from two devices on the detection zones with fire zone LED
*Event log can be monitored via PC software
*Sending event log via RS-232 to PC or printer
*There are two extinguishing operating types; automatic and manual or manual only
*Detection zones can be tested or disabled, 1. and 2. Level relay output, extinguishing output and extinguishing abort button can be disabled
*Inputs and outputs of panel, inputs and outputs of expansion module can be programmed via special PC software. Possibility of assigning gas active, remote alarm, remote reset and many more features to the inputs
*Supervized extiguishing output, second level sounders, gas release output
*Extinguishing mode can be changed remotely with extinguishing status key input
*Fire and fault relays
*Dry contact relay output for fire and fault
*Dry or energized contact options for outputs
*Favorable structure for integration with mechanical systems
*Cross-zone operation can be selected to be active/passive via PC software
*Up to 1000 events log memory
*Adjustable first level delay time to sounders
*Adjustable delay time to detection zones
*Configurable delay and extinguishing time
*Non-latching zone option
*Countdown clock until the starting of extinguishing
*Fire and fault LEDs for each detection zone
*Supervised zone detection inputs, extinguishing hold input, extinguishing abort input, extinguishing activation input, low pressure input.
*Real time clock
Product Code:ML-3313
Brand: Maxlogic & Mavigard by MAVILI

Status indicator units have been allowed to carry the indicators and controllers on ML-322 extinguishing panel to a different location.
- Up to 8 pcs extinguishant condition indicator units can be connected to one pcs fire extinguishing panel.
- Continuity of the communication with extinguishing panel has been controlled. During communication fault condition, user has been informed by audible and visible warnings.
- 4 pcs. of supervised inputs: Abort, Cancel, Extinguishing Status Switch and Remote Reset inputs.
- LED indicator for communication and fault
- 24V DC supply voltage
- Aesthetic design
- Stable sensitivity
PANEL MODELS
Product Code | Description |
---|---|
ML-2222 | Conventional fire alarm control panel, 2 zone |
ML-2224 | Conventional fire alarm control panel, 4 zone |
ML-2228 | Conventional fire alarm control panel, 8 zone |
CONVENTIONAL BUTTONS
Product Code:ML-2710.ES
Brand: Maxlogic & Mavigard by MAVILI

Easy to use, innovative test key designed according to EN 12094-3, advanced technology resetting function and the features of the extinguishing emergency stop button having practical accessories are below.
- Compatible with EN 12094-3
- Compatible with surface and flush mounting
- Compatible with all conventional extinguishing panels
- User friendly
- IP22D protection class
- Protection cover
- Easily resettable
- High and stable operating performance
Product Code:ML-2710.MR
Brand: Maxlogic & Mavigard by MAVILI

Easy to use, innovative test key designed according to EN 12094-3, advanced technology resetting function and the features of the extinguishing hand release button having practical accessories are below.
- Compatible with EN 12094-3
- Compatible with surface and flush mounting
- Compatible with all conventional extinguishing panels
- User friendly
- IP22D protection class
- Protection cover
- Easily resettable
- High and stable operating performance
Conventional gas alarm systems are used to detect carbon monoxide in closed parking lots. Carbon monoxide threatens human life when it reaches a certain density in the environment. Conventional gas alarm systems designed to protect people in the neighborhood from the fatal effects of carbon monoxide trigger ventilation systems in parking lots to evacuate gas after detection.
CONVENTIONAL GAS ALARM CONTROL PANEL
Product Code:ML-4218
Brand: Maxlogic & Mavigard by MAVILI

Conventional Gas Alarm Control Panels, offering stable performance are produced by use of surface mount technology with modern exterior design and programmability.
- 2×16 character LCD with backlight and LED indicators for faults and system conditions.
- 2-level alarm that gas detectors detect can be shown
- 2 alarm relays (for alarm level 1 and 2) and 1 fault relay output for controlling other devices and sending signal to other systems
- Possibility to easily use via few buttons on the panel
- A different relay output for each alarm level. For 8 zones, 16 relay outputs are available in total.
- Supervised conventional zone inputs and sounder outputs
- Some features of panel can be controlled by remote control inputs. System can be switched into alarm and fault mode, alarm mode can be deactivated and system can be reset by using the remote control inputs.
- 8 zone inputs
GD2R SERIES GAS DETECTOR

Conventional carbon-monoxide gas detectors detect gas leakage in closed areas like home, garage etc. Gas detectors with electrochemical sensor have stable sensitivity and high performance.
Gas detectors have 2 level threshold. When the gas in the ambient reaches 50ppm,the gas detector goes into 1st level alarm. If gas concentration reaches 200ppm, the gas detector goes into 2nd level alarm. When the gas concentration in the ambient reaches below 50 ppm, the gas detector automatically turns back to its normal operating condition.
GD2R SERIES GAS DETECTOR MODELS
Product Code | Description |
---|---|
GD2R-12EC | Carbon monoxide gas detector (CO), 12V DC, 2-level alarm output, electrochemical |
GD2R-24EC | Carbon monoxide gas detector (CO), 24V DC, 2-level alarm output, electrochemical |
GD2R-220EC | Carbon monoxide gas detector (CO), 230V AC, 2-level alarm output, electrochemical |